Electric Fence Perimeter Security
To view on your phone
: click here
FENCE HAWK PLUS order here
Electric Fence Perimeter Security – Commercial
Commercial Application
Factory Roof and Wall Extension Five (5) 6″ spaced wires to deter wall climbers.
Since the voltage pulse only lasts 50 to 500 microseconds (0.00005 to 0.0005 seconds), this is a good trick. But because we can do this, we know when the fence is being shorted, grounded or jumpered
This technology also allows the he Fence Hawk Plus™ to give a separate warning for low voltage conditions, which are almost always caused by weeds growth.
There are some other conditions that can cause low voltage, too, but the point is this: low voltage conditions should not generate a full-scale alert, which would be the equivalent of a false alarm.
A small voltage drain from vegetation will still allow the fence to give a painful shock. This needs to be cleaned before fence drops to an unusable level.
The goal here is to alert someone to clean the fence before the voltage drain makes the fence ineffective.
This method of monitoring also prevents false alarms from nearby lightning strikes. A Fence Hawk Plus™ can take a half million volt lightning strike – directly on the fence – without damage, and without generating a false alarm.
Our warranty includes lightning damage, and does not require lightning protection on the fence or array.
.
“Description of Indicators and Adjustments”
Input Power Requirements: 10 to 16 DC.
Power Usage: The input power usage is 0.3 watts. Current consumption is 0.025 amps at 12 volts.
High Voltage Input Pulse: Accepts up to 25,000 volt pulse. If lightning strikes the fence, the Fence Hawk Plus will survive over a half million volt pulse without damage.
Pulse Width Accepted: 50 microseconds to 50 milliseconds.
Pulse Period Accepted: 5 hertz to 0.5 hertz (from 5 pulses per second to 2 seconds between pulses.)
Low Voltage Output (Weeds) Terminal IO5-IO6: Contact closure rated 0.5 amps @ 60 volts DC and 0.5 amps at 30 volts AC. This is sufficient for most piezo sounders. This maintenance output activates when the high voltage input pulse level drops below the “set-point level,” which is variable from 1.5 k-volt to 8 k-volts. This is sufficient for most fence and array applications.
No Voltage Output (Intrusion) Terminal IO7-IO8: Contact closure rated 0.5 amps @ 60 volts DC and 0.5 amps at 30 volts AC. This is sufficient for most alarm and/or communication circuits, but most sirens will require a power contact or relay. This output activates when high voltage input pulse drops below 0.2kv (200 volts).
Automatic Reset: All circuits will reset when the fence voltage returns to normal operating levels.
On some installations, a latching circuit or latching relay may be desired to hold the alarm “on” until manually reset. Please refer to the installation booklet for more details. The manual is at the bottom of this page.
This electric fence EOL (End Of Line) control (voltage monitor) is designed to connect to any standard 12 volt security alarm control panel that is currently available on the market.
If the unit is not connected or powered by an alarm control panel, but instead installed in a “stand alone” configuration, you will need to add the following components to your circuit.
You will need a 12 volt source, which usually consists of an AC to 12 volt DC “plug-in” supply that will continuously charge a 12 volt battery (4amp-hour sealed gel cell) that will maintain the fence monitoring function in the event of a utility power loss. This is then connected to, and powers the Fence Hawk Plus fence voltage monitor.
Since the power interruption break-in is usually momentary, a 12 volts DC latching relay is usually used to power an alarm which may consist o a siren, dialer and/or other devices that are connected to the Fence Hawk Plus to announce a break of the surrounding fence circuit.
INDICATOR LIGHTS (LEDs)
LED 1 :: This indicator is illuminated in concert with fence pulse. When the controls and adjustments are set correctly this indicator should blink/flash with every voltage pulse that is applied to the fence.
LED 2 :: This indicator is illuminated in concert with the normally open (NO) contacts of X2 to provide an alert when the fence voltage drops to a point where the fence generally needs cleaning. This is an adjustable value which is usually set about 500 volts below the operating fence voltage. The high voltage output from your fence charger is reasonably consistent, but will still vary up to 200-300 volts or more within any normal fence usage and environment.
This indicator has a time delay set at 60 seconds or more to allow for momentary and partial loss of voltage usually caused by wind and other temporary cases. This time delay is adjusted with VR2 and is usually set for the maximum delay.
Even with identical equipment, every fence has a different set of environmental conditions that will change the working voltage of your fence, so settings that work for one fence may not work well for another fence.
LED 3 :: This indicator indicates that the Fence Hawk Plus is producing the 5 volt circuit power required for stable operation.
LED 4 :: This indicates a loss of fence voltage and closes the intruder alarm contacts. This occurs when the fence voltage becomes less than the voltage point set with VR4 and indicates a loss of fence voltage which is most often indicates an intrusion. The normal usage delay is 4 seconds which is preset at the factory.
This voltage level is adjustable with VR4 to allow for voltage noise on the fence which can be generated from several sources, which may not have anything to do with your fence. Your fence is essentially a massive antenna which will and does receive voltages signals from various extraneous sources. This interference problem is solved by setting the alarm voltage threshold slightly above the noise threshold. This is usually in the range between 500 and 1,000 volts.
This adjusted with the voltmeter probe inserted into IO-9. Remember that 0.1 volts reading is 450 volts, an adjustment of 0.1 to 0.2 volts is pretty much what
This alarm can also be delayed for specific installations that require a delay before providing an alarm when fence voltage is lost usually because of a broken or cur fence wire. This alarm may also be delayed for up to 60 seconds and is set by adjusting VR3. The factory setting for this delay is set at 4 seconds for normal operation. A longer delay is only used to allow entry when the controls are inside the protected perimeter, although this is better served with a simple remote control device.
The voltage setting is adjusted with VR1. The time delay that is adjusted with VR2 allows for the normal variation of the fence voltage of 200 to 300 volts that will occur from a variety of sources. That voltage level (VR1) in conjunction with 60 plus seconds of delay (VR2) will eliminate 99.9% of false alarms from blowing trash, grass and weeds.
Set the voltage read at IO -10 at 0.04 to 0.06 volts lower than the cusp reading. This will allow for normally occurring fence voltage fluctuations without creating unwanted false alarms.
During normal operation this intermittent indicator will flash once for every fence pulse working at the correct set voltage. When/if it stops flashing, this indicates that fence voltage is less than the voltage setting as described in LED2 operation
INPUT/OUTPUT TERMINAL CONNECTIONS
IO-1 :: IO-2
IO-1 is the input to the Fence Hawk Plus from the voltage divider usually mounted directly to the fence. Its where the actual voltage is measured.
Terminal IO-1 is the pulsed input from the fence voltage divider that is usually directly mounted to, and connected to the high voltage wire. This is usually connected at the far end of the high voltage fence loop.
IO-2 is ground and is connected to IO-4. All ground connections including earth ground should be interconnected.
IO-3 :: IO-4
12 volt power positive (+) is to be connected to terminal IO-3. While the unit is designed for standard 12 volt DC input, it will fully function at any voltage between 10vdc and 16vdc where 12vdc is the nominal input voltage. IO4 is earth and system ground.
Terminals IO-4 and IO-2 are interconnected and common and should be connected to earth ground, the same as the ground side of the fence sensor that is mounted directly to/on the fence. This common ground should be hard wired to the circuit ground. We suggest that all your grounds are connected together, as this is usually done through your ground wires on your fence, which should be all connected together.
Isolated Outputs
IO-5 :: IO-6
These two points are across the electrically isolated normally open contacts of the on-board relay X1. This relay is normally used as the “low voltage” or “maintenance” relay. See: Setup and Operation
These are electrically isolated normally-open (NO) contacts which are rated at 0.5 amps at 30 volts, and are sized to connect directly to a security control panel. If your fence is not connected to, or part of a security system, then an auxiliary relay should be utilized to provide the current and voltage rating that your equipment requires.
IO-9 :: IO-10
These are the actual voltage measurement points for the low voltage (10) set-point voltage which is usually adjusted to 1000 volts below the actual fence voltage. These test points have been provided for ease of measuring and adjustment.
The no voltage (9) set-point voltage is usually set for 1000 volts to 1500 volts above zero volts. See setup in the following chapter.
Using the voltage multiplier of 4400, it will measure less than 3 volts and will vary depending upon what brand of fence charger you are using and the condition of your fence.
There are several areas in the circuitry where the voltage is reduced, and then reduced again to a usable level. The actual voltage value of the fence voltage pulse is divided several times to a final voltage reading that can be easily handled which is 1/4400 of the actual value of the voltage pulse that is on the fence. This voltage value can be read at IO-10 for LED1 from blink to off and will provide the actual fence voltage when multiplied by 4,400 times. Adjust VR1 to where the LED1 is right ate the point it blinks. Now, read the voltage @ IO-10 and multiply times 4400 to determine the actual voltage at/on the fence.
Refer to or click Instruction Manual for more information.
.
USER OPERATIONAL GUIDE
This high voltage sensor – Fence Hawk Plus™ – takes an electric fence charger pulse and analyzes it for peak voltage, pulse width and period. The Fence Hawk Plus™ can accurately measure voltage pulses from almost any fence charger or pulse source, including the spark plug voltage on a gasoline engine.
For best results, the Fence Hawk Plus usually installed at the very end of the fence circuit, where the fence charger is installed at the very beginning of the fence.
The design algorithm used in this device was determined for stability, longevity, and reliability under a wide set of usage parameters. (Patents pending.)
The LED 1 will flash for every pulse that is higher than the maintenance voltage. The maintenance threshold voltage is set at 6 kv at the factory and is user-adjustable via (VR 1). Every fence is different, even with identical equipment, so the Fence Hawk Plus should be adjusted for every unique fence installation.
This “maintenance set-point voltage” is usually set about 1 kv to 2 kv less than the fence energizer output. Then creeping weed growth will be noticed before the fence voltage drops below an effective level.
This maintenance voltage is adjustable from 3.0 kv to 12.0 kv. If flora (grass, bushes, limbs and leaves) partially load or partially short out the high voltage and reduce the effective pulse voltage to below the adjustable maintenance level voltage set point, then the LED 2 will light and the maintenance contacts will close.
The maintenance function (Weed Alert™ LED 2) has approximately a 100 second adjustable delay, to avoid false alarms from wind and other variables. This delay is adjusted via VR2. The voltage level is adjusted via VR1 and measured at IO-10.
When the grass or other debris is removed and the charger pulse voltage is restored to working level, then the maintenance alarm will reset itself and the maintenance contacts will open.
When the fence voltage wire is cut or broken, the pulse voltage drops and is essentially lost, the “no voltage” contacts will close. There is a factory set delay of 5 seconds before the LED 4 will light and the alarm contact closes, to eliminate false alarms from spurious voltage spikes. This time delay can be adjusted via VR 3 and measured at IO-9.
The algorithm used in this circuit also eliminates false alarms from reverse pulses that may occur from close proximity lightning strikes. If the voltage drop is intermittent the circuit will reset itself without generating an alarm. (For some security applications, a latching relay contact may be desired on some output relays.)
This device is designed for long life with ease and consistency of operation. All units have a one year warranty that includes lightning damage.
.
USER GUIDE
The Fence Hawk Plus™ user manual in pdf format
The Fence Hawk Plus™ user manual in doc format
.
WARRANTY
Each unit is guaranteed for a period of one years (12 months) from the date of retail sale. The warranty INCLUDES lightning damage. We reserve the right to either repair or replace the unit, at our discretion.
For more Information about the Fence Hawk Plus Monitor, refer to or click the link below.
Fence Hawk Plus Instruction Manual
.